CLEAR STORAGE 1     ,008015,022026,030037,044,049,053053N000000N00001026                                         1
 CLEAR STORAGE 2     L068116,105106,110117B101/I9I#071029C029056B026/B001/0991,001/001117I0?                      2
 BOOTSTRAP           ,008015,022029,036040,047054,061068,072/061039              ,0010011040                      3
0                          FORTRAN COMPILER -- LOADER PHASE -- PHASE 52B                                  PAGE    1
0 SEQ PG LIN  LABEL  OP    OPERANDS                                            SFX CT  LOCN  INSTRUCTION TYPE  CARD
 
  101                JOB   FORTRAN COMPILER -- LOADER PHASE -- PHASE 52B
  102                CTL   6611
  103         *
  104         * RELOCATABLE FUNCTION ROUTINES AND SUBROUTINES ARE LOADED.
  105         * A TABLE OF THE STARTING ADDRESSES OF THESE ROUTINES IS
  106         * CREATED.
  107         *
  108         * RELOCATION OF RELOCATABLE FUNCTIONS IN THE 1401 FORTRAN
  109         * COMPILER IS ACCOMPLISHED BY TAGGING THE LOAD INSTRUCTION IN
  110         * LOCATION 40, AND THE SUBSEQUENT SET WORD MARK INSTRUCTIONS, TO
  111         * INDICATE WHAT FIELDS ARE TO BE RELOCATED.  IT IS ASSUMED THAT
  112         * THEY ARE RELOCATED BY THE LOAD ADDRESS LESS 2000, SINCE THEY
  113         * ARE ASSEMBLED TO BE LOADED AT 2000.  THE UTILITY THAT CONVERTS
  114         * AUTOCODER DECKS TO RELOCATABLE FORM ASSUMES ADDRESSES ABOVE
  115         * 2000 ARE TO BE RELOCATED.
  116         *
  117         * IF THE INDEX TAG OF THE A FIELD OF THE LOAD INSTRUCTION HAS A
  118         * AND B ZONES, IT MEANS THE B ADDRESS OF THE LOAD INSTRUCTION AND
  119         * BOTH ADDRESSES OF THE SET WORD MARK INSTRUCTIONS, EXCEPT THOSE
  120         * THAT ARE 040, ARE TO BE RELOCATED.  OTHERWISE THEY ARE NOT TO
  121         * BE RELOCATED.  IF THE INDEX TAG OF THE B ADDRESS OF THE LOAD
  122         * INSTRUCTION HAS AN A ZONE IT INDICATES THAT ONLY THE B ADDRESS
  123         * (WORD MARK + 4--6) OF THE FIRST FIELD IS TO BE RELOCATED,  IF
  124         * IT HAS AN B ZONE IT INDICATES THAT ONLY THE A ADDRESS (WORD
  125         * MARK + 1--3) IS TO BE RELOCATED.  IF IT HAS BOTH A AND B ZONES
  126         * IT INDICATES THAT BOTH ADDRESSES ARE TO BE RELOCATED.
  127         *
  128         * IF THE INDEX TAG OF EITHER ADDRESS IN A SET WORD MARK
  129         * INSTRUCTION HAS AN A ZONE IT INDICATES THAT ONLY THE B ADDRESS
  130         * (WORD MARK + 4-6) OF THE TAGGED FIELD IS TO BE RELOCATED,  IF
  131         * IT HAS AN B ZONE IT INDICATES THAT ONLY THE A ADDRESS (WORD
  132         * MARK + 1-3) IS TO BE RELOCATED.  IF IT HAS BOTH A AND B ZONES
  133         * IT INDICATES THAT BOTH ADDRESSES ARE TO BE RELOCATED.
  134         *
  135         * THE BEGINNING OF THE SERIES ROUTINE USED BY THE TRANSCENDENTAL
  136         * FUNCTIONS IS MARKED BY UNDERSCORE CHARACTERS (11-7-8) IN
  137         * COLUMNS 1-5 OF THE FIRST LOAD CARD.  THE BASE ADDRESS IS SAVED
  138         * AT THIS POINT IN SERBAS.  THEN, ADDRESSES ABOVE 4K, WHICH ARE
  139         * ABOVE 14K, ARE CONVERTED TO ADDRESSES ABOVE 2K, AND RELOCATED
  140         * BY SERBAS.  THIS IS DONE SO THAT THE TRANSCENDENTAL FUNCTION
  141         * ROUTINES CAN ACCESS ADDRESSES WITHIN THE SERIES FUNCTION.
  142         *
  143         X1     EQU   89                                                          0089
  144         X2     EQU   94                                                          0094
  145         X3     EQU   99                                                          0099
  146         *
  147         * STUFF IN THE RESIDENT AREA
1                          FORTRAN COMPILER -- LOADER PHASE -- PHASE 52B                                  PAGE    2
0 SEQ PG LIN  LABEL  OP    OPERANDS                                            SFX CT  LOCN  INSTRUCTION TYPE  CARD
 
  148         *
  149         PHASID EQU   110  PHASE ID, FOR SNAPSHOT DUMPS                           0110
  150         FUNC1  EQU   111  SWITCH TO SELECT FIRST RELOCATABLE FUNC                0111
  151         SINCOS EQU   118  SAW SINF OR COSF IF NO WM                              0118
  152         FUNCN  EQU   139  SWITCH TO SELECT LAST RELOCATABLE FUNC                 0139
  153         GOTXL  EQU   185  XLINKF WAS LOADED                                      0185
  154         RELTAB EQU   188  TOP OF RELOCATABLE FUNCTIONS & 1                       0188
  155         ARYTOP EQU   194  TOP OF ARRAYS IN OBJECT CODE                           0194
  156         SNAPSH EQU   333  CORE DUMP SNAPSHOT                                     0333
  157         TOPCOR EQU   688  TOP CORE ADDRESS FROM PARAM CARD                       0688
  158         LOADNX EQU   700  LOAD NEXT OVERLAY                                      0700
  159         CLEARL EQU   707  CS AT START OF OVERLAY LOADER                          0707
  160         CDOVLY EQU   769  1 IF RUNNING FROM CARDS, N IF FROM TAPE                0769
  161         TPREAD EQU   780  TAPE READ INSTRUCTION IN OVERLAY LOADER                0780
  162         LOADXX EQU   793  EXIT FROM OVERLAY LOADER                               0793
  163         CLRBOT EQU   833  BOTTOM OF CORE TO CLEAR IN OVERLAY LOADER              0833
  164         *
  165         * STUFF IN PREVIOUS PHASE (52A)
  166         *
  167         EXLINK EQU   840   139 I XLINKF ENTRY                                    0840
  168         USER1  EQU   876   127 R USER FUNCTION ENTRY                             0876
  169         SX2    EQU   927                                                         0927
  170         CONBOT EQU   930   BOTTOM OF CONSTANTS - 1                               0930
  171         ARYBOT EQU   933   BOTTOM OF ARRAYS - 1                                  0933
  172         *
  173                ORG   333                                                                0333
  174         LOADD1 EQU   *&1          LOAD ADDRESS                                   0333
  175    333         H     333                                                      4  0333  . 333                4
  176    337  BEGINN CS    80                                                       4  0337  / 080                4
  177    341         MCW   X3,SX3                                                   7  0341  M 099 W35            4
  178    348         SBR   X3,1&X3                                                  7  0348  H 099 0?1            4
  179    355         SW    1,40           SET WORD                                  7  0355  , 001 040            4
  180    362         SW    47,54            MARKS TO                                7  0362  , 047 054            4
  181    369         SW    61,68              READ RELOCATABLE                      7  0369  , 061 068            5
  182    376         SW    72                   SUBPROGRAMS                         4  0376  , 072                5
  183    380         MCW   CDOVLY,RDCARD  CARDS IF 1, TAPE IF NOP                   7  0380  M 769 /60            5
  184    387         B     RDREC          SKIP BOUNDARY -- FIVE BRACKETS            4  0387  B /49                5
  185    391         MCW   83,X2                                                    7  0391  M 083 094            5
  186    398         MN    0&X2                                                     4  0398  D 0!0                5
  187    402         MN                                                             1  0402  D                    5
  188    403         SBR   TSTUND&6                                                 4  0403  H |95                6
  189    407         MCW   KUND1       TOO BIG IF THIS GETS CLOBBERED               4  0407  M V65                6
  190    411         NOP                                                            1  0411  N                    6
  191    412  OUTER  MCW   X3,ADD14K&3                                              7  0412  M 099 436            6
  192    419         MZ    BRANCH,ADD14K&2  X3 ZONE                                 7  0419  Y V66 435            6
  193    426         MCW   K14K,X3                                                  7  0426  M V60 099            6
  194         * WHY NOT SBR  X3,0-0 ???
  195    433  ADD14K NOP   0-0         SUBTRACT 2000 FROM X3 BECAUSE                4  0433  N 000                6
  196    437         SAR   X3            RELOCTABLES ORG AT 2000                    4  0437  Q 099                7
  197    441  GETUND B     RDREC                                                    4  0441  B /49                7
1                          FORTRAN COMPILER -- LOADER PHASE -- PHASE 52B                                  PAGE    3
0 SEQ PG LIN  LABEL  OP    OPERANDS                                            SFX CT  LOCN  INSTRUCTION TYPE  CARD
 
  198    445  CHKUND C     5,KUND4     DOES RECORD BEGIN WITH UNDERLINES            7  0445  C 005 V70            7
  199    452         BU    NOTUND      NO                                           5  0452  B 468 /              7
  200    457         MCW   X3,SERBAS   SAVE BASE ADDRESS FOR SERIES FUNCTION        7  0457  M 099 V73            7
  201    464         B     GETUND      YES, GET ANOTHER RECORD                      4  0464  B 441                7
  202    468  NOTUND MCW   AFUNC1,X1   NEXT LOAD SWITCH                             7  0468  M V63 089            7
  203    475  SBRNOP SBR   AFUNC1,1&X1   NOP FOR SECOND PASS SIN FLAG               7  0475  H V63 0|1            8
  204    482         C     X1,AFUNCN   END OF LOAD FLAGS?                           7  0482  C 089 V76            8
  205    489         BE    SWITCH      YES                                          5  0489  B T59 S              8
  206    494         MCW   SBR,SBRNOP                                               7  0494  M V77 475            8
  207    501         C     SX2,AUSER1                                               7  0501  C 927 V80            8
  208    508  SWICH1 BE    GOTUSR      USER FUNCTIONS?                              5  0508  B U23 S              8
  209    513  RETUSR MCW   SX2,X2      DECREMENT                                    7  0513  M 927 094            9
  210    520         C     0&X2          FUNCTION TABLE                             4  0520  C 0!0                9
  211    524         SAR   SX2             POINTER                                  4  0524  Q 927                9
  212    528         BW    SKIP,0&X1   DON'T NEED DECK IF WM IN LOAD FLAG           8  0528  V T35 0|0 1          9
  213    536  MCWNOP MCW   NOP,SWICH2  ALLOW STORING LOAD ADDRESS UNLESS NOP        7  0536  M V81 583            9
  214    543  TSTREL BWZ   NOREL,42,2  NO RELOCATION                                8  0543  V /31 042 2          9
  215    551         MN    46,LOAD&6   LOAD FROM WHERE                              7  0551  D 046 578           10
  216    558         CHAIN 5                                                                             MACRO
  217                MN                                                             1  0558  D           GEN     10
  218                MN                                                             1  0559  D           GEN     10
  219                MN                                                             1  0560  D           GEN     10
  220                MN                                                             1  0561  D           GEN     10
  221                MN                                                             1  0562  D           GEN     10
  222    563         MZ    46,LOAD&6   LOAD TO WHERE                                7  0563  Y 046 578           10
  223    570         MN                DONT CLOBBER X3 ZONE TAG                     1  0570  D                   11
  224    571         MZ                                                             1  0571  Y                   11
  225    572  LOAD   LCA   0,0&X3      LOAD THE FIELD FROM THE RECORD               7  0572  L 000 0?0           11
  226    579         SBR   X2                                                       4  0579  H 094               11
  227    583  SWICH2 NOP   MZ45        SKIP STORING LOAD ADDRESS IF BRANCH          4  0583  N 608               11
  228    587         MCW   SX2,X1                                                   7  0587  M 927 089           11
  229    594         SBR   3&X1,1&X2   STORE FUNCTION LOAD ADDRESS                  7  0594  H 0|3 0!1           11
  230    601         MCW   BRANCH,SWICH2  SKIP OVER STORING LOAD ADDRESS            7  0601  M V66 583           12
  231    608  MZ45   MZ    45,SAVZON   RELOCATION TAG FOR FIRST FIELD               7  0608  Y 045 V82           12
  232    615         B     RELOC                                                    4  0615  B S17               12
  233    619         S     X1&1                                                     4  0619  S 090               12
  234    623  LOOP   C     50&X1,A40   WHY NOT BCE NORELX,50&X1,0 ???               7  0623  C 0V0 V85           12
  235    630         BE    NORELX      AT WM ADDRESS 040 OR AT 1040 INSTR           5  0630  B |11 S             12
  236    635         MCW   50&X1,SWCW&3                                             7  0635  M 0V0 667           13
  237    642         MZ    BRANCH,SWCW&2  X3 TAG                                    7  0642  Y V66 666           13
  238    649         BCE   SWCW,SWCW,)                                              8  0649  B 664 664 )         13
  239    657         MCW   SW,SWCW     IN CASE WE ARE DOING THE B FIELD             7  0657  M V86 664           13
  240    664  SWCW   SW    0&X3  SET OR CLEAR RELOCATED WORD MARK                   4  0664  , 0?0               13
  241    668         SAR   X2                                                       4  0668  Q 094               13
  242    672         B     CONT  BRANCH AROUND PHASE LOADER                         4  0672  B 934               14
  243    676         NOP   0                                                        4  0676  N 000               14
  244    680         DCW   @}@                                                      1  0680              GMARK   14
  245                ORG   201                                                                0201
  246    203         DSA   LOADD1    LOAD ADDRESS FOR CARD-TO-TAPE PROGRAM          3  0203  333                 15
  247                EX    LOADXX                                                            B 793               16
1                          FORTRAN COMPILER -- LOADER PHASE -- PHASE 52C                                  PAGE    4
0 SEQ PG LIN  LABEL  OP    OPERANDS                                            SFX CT  LOCN  INSTRUCTION TYPE  CARD
 
  248                JOB   FORTRAN COMPILER -- LOADER PHASE -- PHASE 52C
  249                ORG   934                                                                0934
  250         LOADDD EQU   *&1          LOAD ADDRESS                                   0934
  251    934  CONT   MZ    49&X1,SAVZON  RELOCATION TAG FROM SW INSTRUCTION         7  0934  Y 0U9 V82           19
  252    941         B     RELOC                                                    4  0941  B S17               19
  253         * ADD EITHER 3 OR 4 TO X1 TO GET TO NEXT SW ADDRESS
  254         * THIS WOULD BE SIMPLER IF SBR/NOP X1,1&X1 THEN SBR X1,3&X1 ???
  255    945  NOPADD NOP   K4,X1  SOMETIMES ADD, SOMETIMES NOP                      7  0945  N V87 089           19
  256    952  ADDNOP A     K3,X1  SOMETIMES ADD, SOMETIMES NOP                      7  0952  A V88 089           19
  257    959         BCE   EXCH43,NOPADD,A                                          8  0959  B 993 945 A         19
  258    967         MCW   ADD,NOPADD                                               7  0967  M V89 945           20
  259    974         MCW   NOP,ADDNOP                                               7  0974  M V81 952           20
  260    981         BCE   NOPADD,SWCW,)  ???                                       8  0981  B 945 664 )         20
  261    989         B     LOOP                                                     4  0989  B 623               20
  262    993  EXCH43 MCW   NOP,NOPADD                                               7  0993  M V81 945           20
  263  1 000         MCW   ADD,ADDNOP                                               7  1000  M V89 952           21
  264  1 007         B     LOOP                                                     4  1007  B 623               21
  265         *
  266         * DONE WITH RELOCATION OF ONE DECK
  267         *
  268  1 011  NORELX MCW   46,WHERE    TOP ADDRESS LOADED?                          7  1011  M 046 V92           21
  269  1 018         MCW   NOP,NOPADD  RESET ADD 3/4                                7  1018  M V81 945           21
  270  1 025         MCW   ADD,ADDNOP    TOGGLE                                     7  1025  M V89 952           21
  271  1 032         B     RDREC                                                    4  1032  B /49               21
  272  1 036         BCE   EXEND,68,B  EX CARD?                                     8  1036  B |56 068 B         22
  273  1 044         BCE   EXEND,40,/  END CARD?                                    8  1044  B |56 040 /         22
  274  1 052         B     TSTREL                                                   4  1052  B 543               22
  275  1 056  EXEND  MCW   WHERE,*&11  CAN WE USE LOAD&6 HERE ???                   7  1056  M V92 |73           22
  276  1 063         MZ    BRANCH,*&3  X3 TAG                                       7  1063  Y V66 |72           22
  277  1 070         NOP   0&X3                                                     4  1070  N 0?0               22
  278  1 074         SAR   X3                                                       4  1074  Q 099               23
  279  1 078         SBR   SX3                                                      4  1078  H W35               23
  280  1 082         SBR   X3,1&X3     NEXT FUNCTION LOAD ADDRESS                   7  1082  H 099 0?1           23
  281  1 089  TSTUND BCE   OUTER,0,_   NOT TOO BIG IF STILL UNDERLINE               8  1089  B 412 000 _         23
  282  1 097         CS    332                                                      4  1097  / 332               23
  283  1 101         CS                                                             1  1101  /                   23
  284  1 102         CC    1                                                        2  1102  F 1                 23
  285  1 104         MCW   ERROR2,270                                               7  1104  M W28 270           24
  286  1 111         W                                                              1  1111  2                   24
  287  1 112         CC    1                                                        2  1112  F 1                 24
  288  1 114         BCE   HALT,CDOVLY,1                                            8  1114  B /27 769 1         24
  289  1 122         RWD   1                                                        5  1122  U %U1 R             24
  290  1 127  HALT   H     HALT                                                     4  1127  . /27               24
  291         *
  292         * NO RELOCATION, SIMPLY EXECUTE THE LOAD CODE
  293         *
  294  1 131  NOREL  SBR   71,NORELX                                                7  1131  H 071 |11           24
  295  1 138         MCW   BRANCH,68                                                7  1138  M V66 068           25
  296  1 145         B     40                                                       4  1145  B 040               25
  297         *
1                          FORTRAN COMPILER -- LOADER PHASE -- PHASE 52C                                  PAGE    5
0 SEQ PG LIN  LABEL  OP    OPERANDS                                            SFX CT  LOCN  INSTRUCTION TYPE  CARD
 
  298         * READ A RECORD OF THE RELOCATABLE LIBRARY EITHER
  299         * FROM CARD OR TAPE
  300         *
  301  1 149  RDREC  SBR   RDRECX&3                                                 4  1149  H /87               25
  302  1 153         MCW   KB1,1   IN CASE IT WAS A GM IN THE PREV RECORD           7  1153  M W29 001           25
  303  1 160  RDCARD R     RDRECX  NOP IF LOADED FROM TAPE                          4  1160  1 /84               25
  304  1 164  REREAD MCW   KP9,ERRCNT                                               7  1164  M W30 W31           25
  305  1 171  RDTAPE RT    1,1                                                      8  1171  M %U1 001 R         26
  306  1 179         BER   TAPERR                                                   5  1179  B /88 L             26
  307  1 184  RDRECX B     0                                                        4  1184  B 000               26
  308         *
  309  1 188  TAPERR BSP   1                                                        5  1188  U %U1 B             26
  310  1 193         S     KP1,ERRCNT                                               7  1193  S W32 W31           26
  311  1 200         BWZ   RDTAPE,ERRCNT,B                                          8  1200  V /71 W31 B         26
  312  1 208         NOP   3333                                                     4  1208  N C33               27
  313  1 212         H                                                              1  1212  .                   27
  314  1 213         B     REREAD                                                   4  1213  B /64               27
  315         *
  316         * RELOCATE FIELDS OF LOADED INSTRUCTIONS
  317         *
  318  1 217  RELOC  SBR   RELOCX&3                                                 4  1217  H T34               27
  319  1 221         BWZ   RELOCX,SAVZON,2  NO RELOCATION                           8  1221  V T31 V82 2         27
  320  1 229         BWZ   RELX1,SAVZON,S   B FIELD RELOCATION ONLY                 8  1229  V S88 V82 S         27
  321  1 237         MCW   X3,SX3                                                   7  1237  M 099 W35           27
  322  1 244         BWZ   RELNZ1,4&X2,2    IS RELOCATED FIELD BELOW 4K             8  1244  V S66 0!4 2         28
  323  1 252         MCW   SERBAS,X3        NO, MUST BE ABOVE 14K = 16K-2K          7  1252  M V73 099           28
  324  1 259         MZ    *-4,4&X2         THOUSANDS TAG SET TO 2                  7  1259  Y S61 0!4           28
  325  1 266  RELNZ1 MA    X3,4&X2          RELOCATE A FIELD                        7  1266  # 099 0!4           28
  326  1 273         MCW   SX3,X3                                                   7  1273  M W35 099           28
  327  1 280         BM    RELOCX,SAVZON    A FIELD RELOCATION ONLY                 8  1280  V T31 V82 K         29
  328  1 288  RELX1  MCW   X3,SX3                                                   7  1288  M 099 W35           29
  329  1 295         BWZ   RELNZ2,7&X2,2    IS RELOCATED FIELD BELOW 4K             8  1295  V T17 0!7 2         29
  330  1 303         MCW   SERBAS,X3        NO, MUST BE ABOVE 14K = 16K-2K          7  1303  M V73 099           29
  331  1 310         MZ    *-4,7&X2         THOUSANDS TAG SET TO 2                  7  1310  Y T12 0!7           29
  332  1 317  RELNZ2 MA    X3,7&X2          RELOCATE B FIELD                        7  1317  # 099 0!7           30
  333  1 324         MCW   SX3,X3                                                   7  1324  M W35 099           30
  334  1 331  RELOCX B     0                                                        4  1331  B 000               30
  335         *
  336         * DON'T NEED THE FUNCTION
  337         * SKIP UNTIL END OR EX RECORD
  338         *
  339  1 335  SKIP   B     RDREC                                                    4  1335  B /49               30
  340  1 339         BCE   GETUND,40,/                                              8  1339  B 441 040 /         30
  341  1 347         BCE   GETUND,68,B                                              8  1347  B 441 068 B         30
  342  1 355         B     SKIP                                                     4  1355  B T35               31
  343         *
  344         * GOT TO END OF LOAD FLAGS
  345         * START OVER AT SINCOS TO STORE THE ENTRY TABLE
  346         *
  347  1 359  SWITCH NOP   DONE           SECOND TIME IT IS A BRANCH                4  1359  N U41               31
1                          FORTRAN COMPILER -- LOADER PHASE -- PHASE 52C                                  PAGE    6
0 SEQ PG LIN  LABEL  OP    OPERANDS                                            SFX CT  LOCN  INSTRUCTION TYPE  CARD
 
  348  1 363         MCW   BRANCH,SWITCH  ONLY DO THIS ONCE                         7  1363  M V66 T59           31
  349  1 370         SBR   AFUNC1,SINCOS  START OVER AT SINCOS                      7  1370  H V63 118           31
  350  1 377         MCW   SX3,X2                                                   7  1377  M W35 094           31
  351  1 384         SBR   RELTAB,1&X2    RELOCATABLE ENTRY TABLE ADDRESS           7  1384  H 188 0!1           31
  352  1 391         MCW   NOP,SBRNOP                                               7  1391  M V81 475           32
  353  1 398         MCW   NOP,MCWNOP                                               7  1398  M V81 536           32
  354  1 405         MCW   BRANCH,SWICH2  SKIP STORING LOAD ADDRESS                 7  1405  M V66 583           32
  355  1 412         MCW   SX3,SX3D                                                 7  1412  M W35 W38           32
  356  1 419         B     CHKUND                                                   4  1419  B 445               32
  357         *
  358         * DOWN TO USER FUNCTIONS IN THE ADDRESS TABLE
  359         *
  360  1 423  GOTUSR MCW   SX3,SX3C  SAVE FIRST USER FUNCTION ADDRESS               7  1423  M W35 W41           32
  361  1 430         MCW   NOP,SWICH1                                               7  1430  M V81 508           33
  362  1 437         B     RETUSR                                                   4  1437  B 513               33
  363         *
  364  1 441  DONE   MCW   SX3,X3         TOP OF FUNCTION ENTRY TABLE               7  1441  M W35 099           33
  365  1 448         MCW   TOPCOR,X2                                                7  1448  M 688 094           33
  366  1 455         C     0&X2                                                     4  1455  C 0!0               33
  367  1 459         SAR   X2                                                       4  1459  Q 094               33
  368  1 463         SBR   ARYBOT         BOTTOM OF ARRAYS - 1                      4  1463  H 933               33
  369  1 467         C     0&X2                                                     4  1467  C 0!0               34
  370  1 471         SAR   CONBOT         BOTTOM OF CONSTANTS - 1                   4  1471  Q 930               34
  371  1 475         BCE   BLANK,EXLINK,  IS XLINKF LOADED                          8  1475  B V08 840           34
  372  1 483         MCW   EXLINK,X1      YES                                       7  1483  M 840 089           34
  373  1 490         MA    A13,X1         WHY NOT MCW  ARYTOP,13&X1 ???             7  1490  # W44 089           34
  374  1 497         MCW   ARYTOP,0&X1    STORE WITHIN XLINKF                       7  1497  M 194 0|0           34
  375  1 504         CW    GOTXL                                                    4  1504  ) 185               35
  376  1 508  BLANK  MCW   SX3C,X1  FIRST USER FUNCTION ADDRESS                     7  1508  M W41 089           35
  377  1 515         MCW   SX3D,X2  LAST FUNCTION LOAD ADDRESS & 1                  7  1515  M W38 094           35
  378  1 522         SBR   TPREAD&6,934                                             7  1522  H 786 934           35
  379  1 529         SBR   CLRBOT                                                   4  1529  H 833               35
  380  1 533         SBR   LOADXX&3,934                                             7  1533  H 796 934           35
  381  1 540         SBR   CLEARL&3,1696                                            7  1540  H 710 W96           36
  382  1 547         LCA   RELOAD,PHASID                                            7  1547  L W53 110           36
  383  1 554         B     LOADNX                                                   4  1554  B 700               36
  384         *
  385         * DATA
  386         *
  387  1 560  K14K   DSA   14000    14000 IS 16000-2000                             3  1560  !0?                 36
  388  1 563  AFUNC1 DCW   FUNC1    ADDRESS OF FIRST FUNCTION SWITCH                3  1563  111                 36
  389  1 564         DC    #1                                                       1  1564                      36
  390  1 565  KUND1  DCW   @_@      ONE UNDERLINE CHARACTER                         1  1565                      36
  391  1 566  BRANCH B                                                              1  1566  B                   36
  392  1 570  KUND4  DCW   @____@   FOUR UNDERLINE CHARACTERS (11-7-8)              4  1570                      37
  393  1 573  SERBAS DCW   #3       BASE ADDRESS FOR SERIES FUNCTION                3  1573                      37
  394  1 576  AFUNCN DSA   FUNCN&1  ADDRESS OF LAST FUNCTION SWITCH                 3  1576  140                 37
  395  1 577  SBR    SBR                                                            1  1577  H                   37
  396  1 580  AUSER1 DSA   USER1    FIRST USER FUNCTION ENTRY                       3  1580  876                 37
  397  1 581  NOP    NOP                                                            1  1581  N                   37
1                          FORTRAN COMPILER -- LOADER PHASE -- PHASE 52C                                  PAGE    7
0 SEQ PG LIN  LABEL  OP    OPERANDS                                            SFX CT  LOCN  INSTRUCTION TYPE  CARD
 
  398  1 582  SAVZON DCW   #1                                                       1  1582                      37
  399  1 585  A40    DSA   40                                                       3  1585  040                 38
  400  1 586  SW     SW                                                             1  1586  ,                   38
  401  1 587  K4     DCW   4                                                        1  1587                      38
  402  1 588  K3     DCW   3                                                        1  1588                      38
  403  1 589  ADD    A                                                              1  1589  A                   38
  404  1 592  WHERE  DCW   #3                                                       3  1592                      38
  405  1 628  ERROR2 DCW   @MESSAGE 2 - OBJECT PROGRAM TOO LARGE@                  36  1628                      39
  406  1 629  KB1    DCW   #1                                                       1  1629                      39
  407  1 630  KP9    DCW   &9                                                       1  1630                      39
  408  1 631  ERRCNT DCW   #1  TAPE ERROR COUNTER                                   1  1631                      39
  409  1 632  KP1    DCW   &1                                                       1  1632                      40
  410  1 635  SX3    DCW   #3                                                       3  1635                      40
  411  1 638  SX3D   DCW   #3                                                       3  1638                      40
  412  1 641  SX3C   DCW   #3                                                       3  1641                      40
  413  1 644  A13    DSA   13                                                       3  1644  013                 40
  414  1 653  RELOAD DCW   @RELOAD SS@                                              9  1653                      40
  415  1 654         DCW   @}@                                                      1  1654              GMARK   40
  416                ORG   201                                                                0201
  417    203         DSA   LOADDD    LOAD ADDRESS FOR CARD-TO-TAPE PROGRAM          3  0203  934                 41
  418                EX    BEGINN                                                            B 337               42
  419                END                                                                     / 000 080
1                          FORTRAN COMPILER -- LOADER PHASE -- PHASE 52C                                  PAGE    8
0SYMBOL  ADDRESS  SYMBOL  ADDRESS  SYMBOL  ADDRESS  SYMBOL  ADDRESS  SYMBOL  ADDRESS  SYMBOL  ADDRESS  SYMBOL  ADDRESS  

 A13      1644    A40      1585    ADD      1589    ADD14K    433    ADDNOP    952    AFUNC1   1563    AFUNCN   1576   
 ARYBOT    933    ARYTOP    194    AUSER1   1580    BEGINN    337    BLANK    1508    BRANCH   1566    CDOVLY    769   
 CHKUND    445    CLEARL    707    CLRBOT    833    CONBOT    930    CONT      934    DONE     1441    ERRCNT   1631   
 ERROR2   1628    EXCH43    993    EXEND    1056    EXLINK    840    FUNC1     111    FUNCN     139    GETUND    441   
 GOTUSR   1423    GOTXL     185    HALT     1127    K14K     1560    K3       1588    K4       1587    KB1      1629   
 KP1      1632    KP9      1630    KUND1    1565    KUND4    1570    LOAD      572    LOADD1    333    LOADDD    934   
 LOADNX    700    LOADXX    793    LOOP      623    MCWNOP    536    MZ45      608    NOP      1581    NOPADD    945   
 NOREL    1131    NORELX   1011    NOTUND    468    OUTER     412    PHASID    110    RDCARD   1160    RDREC    1149   
 RDRECX   1184    RDTAPE   1171    RELNZ1   1266    RELNZ2   1317    RELOAD   1653    RELOC    1217    RELOCX   1331   
 RELTAB    188    RELX1    1288    REREAD   1164    RETUSR    513    SAVZON   1582    SBR      1577    SBRNOP    475   
 SERBAS   1573    SINCOS    118    SKIP     1335    SNAPSH    333    SW       1586    SWCW      664    SWICH1    508   
 SWICH2    583    SWITCH   1359    SX2       927    SX3      1635    SX3C     1641    SX3D     1638    TAPERR   1188   
 TOPCOR    688    TPREAD    780    TSTREL    543    TSTUND   1089    USER1     876    WHERE    1592    X1         89   
 X2         94    X3         99